[et_pb_section fb_built=”1″ _builder_version=”3.22.3″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” custom_margin=”-36px|auto||auto||” _builder_version=”3.22.3″][et_pb_column type=”4_4″ _builder_version=”3.19″][et_pb_text _builder_version=”3.22.7″]

Transformer Insulation includes, Transformer Oil in the Main Tank and Transformer Winding Insulation.

[/et_pb_text][et_pb_text _builder_version=”3.22.7″ custom_padding=”||0px|||”]

Transformer Oil:

[/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

Function:

It is a Mineral Insulating Oil/Liquid Dilectric which provides following Functions:

  1.  Provides Insulation Between Core, Winding and the tank.
  2. Provides Cooling
  3.  Its Hygroscopic nature is useful in absorbing moisture from the Winding Insulation. 
    [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

    Factors affecting deterioration:

    1.  Voltage transients due to Faults.
    2. Heat due to Overlapping/ improper Cooling.
    3. Filling/topping up operation.
    4. Chemical Reation
    5. Moisture due to leakages and breathing action.
    6. Dirt due to improper breathing action
    7. Ageing of Solid and Liquid Insulation
    8. Oxygen.
      [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

      Corrective Actions:

      1. Filteration/reconditioning.
      2. Reclamation
      3. Re-fining
      4. Replacement.
        [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

        Corona Fault results in :

        1. Hydrogen
          [/et_pb_text][et_pb_text _builder_version=”3.22.7″ custom_padding=”||0px|||”]

          Transformer Oil:

          [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

          Function:

          It is a Solid Insulation of Cellulose material which provides following Functions:

          1. It prevents the shorting of the two windings.
            [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

            Factors affecting deterioration:

            1.  Cellulose degradation, which gives rise to gasses.
            2. Polymerisation of Cellulose.
              [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

              Corrective Actions:

              1. Rewinding
                [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.22.4″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]

                Corona Fault results in :

                1. Hydrogen
                2. Carbon Momoxide
                3. Carbon Dioxide
                  [/et_pb_text][et_pb_text _builder_version=”3.22.7″]

                  Please note that same Switch is also availabe in Circuit Breaker for Local Closing and Tripping.

                  [/et_pb_text][/et_pb_column][/et_pb_row][/et_pb_section]