What is the Duty Cycle/Operating Sequence of Circuit Breaker specified on the Name Plate
Circuit Breaker | SF6CB | VCB

What is the Duty Cycle/Operating Sequence of Circuit Breaker specified on the Name Plate

[et_pb_section fb_built=”1″ _builder_version=”3.17.6″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” _builder_version=”3.19″][et_pb_column type=”4_4″ _builder_version=”3.19″][et_pb_text _builder_version=”3.19.5″ text_font=”Lato||||||||” text_line_height=”1.3em” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] We keep wondering what the heck this sequence on the name plate of the Circuit Brekaer. Lets find it out now. [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.19.9″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] What is the Duty Cycle/…

Circuit Breaker Testing with Standard Test Results
Circuit Breaker | SF6CB | VCB

Circuit Breaker Testing with Standard Test Results

[et_pb_section fb_built=”1″ _builder_version=”3.17.6″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” _builder_version=”3.19″][et_pb_column type=”4_4″ _builder_version=”3.19″ parallax=”off” parallax_method=”on”][et_pb_text _builder_version=”3.19.5″ text_font=”Lato||||||||” text_line_height=”1.3em” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] There are following Commissioning Tests, Diagnostic Tests and Trials of Circuit Breaker. [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.19.9″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] 1) Measurement of Insulation Resistance: Objective: To ensure that each pole of…

Circuit Breaker | VCB

Tripping Circuit of 33 KV Outdoor GO VCB

[et_pb_section fb_built=”1″ _builder_version=”3.17.6″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” _builder_version=”3.19″][et_pb_column type=”4_4″ _builder_version=”3.19″ parallax=”off” parallax_method=”on”][et_pb_text _builder_version=”3.19.4″ text_font=”Lato||||||||” text_line_height=”1.3em” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]There are two Tripping Circuits in the Breaker, Called a Trip Circuit 1 and Trip Circuit 2. Both this Tripping Circuits should have different DC Supply and different Tripping.  Tripping Circuit of VCB can be divided into…

Troubleshooting Circuit Breaker not Closing Electrically Problem in 33 KV Outdoor GO VCB
Circuit Breaker | VCB

Troubleshooting Circuit Breaker not Closing Electrically Problem in 33 KV Outdoor GO VCB

[et_pb_section fb_built=”1″ _builder_version=”3.17.6″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” _builder_version=”3.19″][et_pb_column type=”4_4″ _builder_version=”3.19″ parallax=”off” parallax_method=”on”][et_pb_text _builder_version=”3.19.5″ text_font=”Lato||||||||” text_line_height=”1.3em” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] A very common problem in EHV Substations, Circuit Breaker not closing Electrically.  The Troubleshooting steps are as under: [/et_pb_text][et_pb_text _builder_version=”3.19.3″ text_font=”Lato||||||||” text_line_height=”1.3em” box_shadow_style=”preset1″ custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] Step 1: Basic Checks: Check the DC Supply to…