What is the Duty Cycle/Operating Sequence of Circuit Breaker specified on the Name Plate
| |

What is the Duty Cycle/Operating Sequence of Circuit Breaker specified on the Name Plate

[We keep wondering what the heck this sequence on the name plate of the Circuit Breakaer. Lets find it out now. What is the Duty Cycle/ Operating Sequence of CB? It is the Mechanical Duty requirement to be fulfilled by the  Operating Mechanism of the Breaker and specified on the Name Plate of the Breaker…

Circuit Breaker Testing with Standard Test Results
|

Circuit Breaker Testing with Standard Test Results

[et_pb_section fb_built=”1″ _builder_version=”3.17.6″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” _builder_version=”3.19″][et_pb_column type=”4_4″ _builder_version=”3.19″ parallax=”off” parallax_method=”on”][et_pb_text _builder_version=”3.19.5″ text_font=”Lato||||||||” text_line_height=”1.3em” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] There are following Commissioning Tests, Diagnostic Tests and Trials of Circuit Breaker. [/et_pb_text][et_pb_text module_class=”custom-module” _builder_version=”3.19.9″ text_font=”Lato||||||||” text_line_height=”1.2em” header_font=”||||||||” box_shadow_style=”preset1″ custom_margin=”0px||” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”] 1) Measurement of Insulation Resistance: Objective: To ensure that each pole of…

|

Tripping Circuit of 33 KV Outdoor GO VCB

[et_pb_section fb_built=”1″ _builder_version=”3.17.6″ background_color=”rgba(255,255,255,0.76)” custom_margin=”0px|||0px” custom_padding=”0|0|0|0|false|false”][et_pb_row custom_padding=”0|0px|20.1389px|0px|false|false” _builder_version=”3.19″][et_pb_column type=”4_4″ _builder_version=”3.19″ parallax=”off” parallax_method=”on”][et_pb_text _builder_version=”3.19.4″ text_font=”Lato||||||||” text_line_height=”1.3em” custom_padding=”20px|20px|20px|20px” inline_fonts=”Arial,Georgia,Times New Roman”]There are two Tripping Circuits in the Breaker, Called a Trip Circuit 1 and Trip Circuit 2. Both this Tripping Circuits should have different DC Supply and different Tripping.  Tripping Circuit of VCB can be divided into…

Troubleshooting Circuit Breaker not Closing Electrically Problem in 33 KV Outdoor GO VCB
|

Troubleshooting Circuit Breaker not Closing Electrically Problem in 33 KV Outdoor GO VCB

A very common problem in EHV Substations, Circuit Breaker not closing Electrically.  The Troubleshooting steps are as under: Step 1: Basic Checks: Check the DC Supply to the Breaker. Connect the Multimeter between K1 and K2, it should show full voltage (220V/110VDC). Check, if the Closing Spring are charged, because an NC Spring Charge limit…